18th Edition Wiring Regulations Practice Exam – Paper 1

1 2 3

BS 7671:2018 including Amendment 2:2022 • 60 multiple-choice questions • Pass mark: 65%

1. Which regulation requires installations to be designed to protect persons, livestock, and property?

2. What is the nominal voltage of low voltage systems as defined in BS 7671?

3. Which regulation covers the requirement for competence of persons?

4. What is the maximum disconnection time for a TN system final circuit not exceeding 32 A?

5. Which device provides both overcurrent and residual current protection?

6. What is the minimum RCD rating for socket-outlets ≤32 A in dwellings?

7. Which regulation requires additional protection by RCDs for circuits supplying mobile equipment outdoors ≤32 A?

8. What is the maximum disconnection time for TT systems for final circuits ≤32 A?

9. What is the minimum cross-sectional area of a protective conductor for a 6 mm² live conductor (copper)?

10. Which regulation covers requirements for electrical connections?

11. Which regulation requires main protective bonding?

12. What is the minimum bonding conductor size for gas pipework in a domestic installation (non-PME typical case)?

13. Which regulation defines requirements for isolation?

14. What is the primary purpose of functional switching?

15. Emergency switching must be…

16. Which regulation covers switching off for mechanical maintenance?

17. Which device provides protection against short-circuit currents?

18. What is the maximum earth fault loop impedance (Zs) for a 32 A Type B MCB?

19. Which regulation covers coordination of protective devices?

20. Which device is used to protect against transient overvoltages?

21. Which regulation requires initial verification of every installation?

22. What insulation resistance test voltage is used for circuits ≤500 V?

23. What is the minimum insulation resistance value for low voltage circuits?

24. Which test confirms polarity of socket-outlets?

25. Which regulation requires periodic inspection and testing?

26. What instrument is used to measure earth fault loop impedance?

27. Which test ensures continuity of protective conductors?

28. What is the minimum test current used during RCD testing?

29. Which regulation requires certification after inspection and testing?

30. Which form is issued after initial verification?

31. Which section covers bathrooms?

32. What is the minimum IP rating for equipment in Zone 1 of a bathroom?

33. Which section covers agricultural locations?

34. Which section covers caravan parks?

35. Which section covers marinas?

36. Which section covers medical locations?

37. Which section covers EV charging installations?

38. What is the minimum RCD rating required for EV charging points?

39. Which section covers temporary installations for construction sites?

40. Which section covers exhibitions, shows, and stands?

41. Which regulation introduced AFDDs for certain circuits?

42. AFDDs are primarily designed to protect against…

43. Which regulation requires SPDs where overvoltage consequences could be serious?

44. Which section covers prosumer installations?

45. Which regulation requires consideration of energy efficiency in design?

46. Proximity of wiring systems to other services is covered by:

47. Which regulation requires protective devices to be selected considering coordination?

48. Which regulation requires consideration of external influences?

49. Which regulation requires an electrical installation certificate after completion?

50. Which certificate is issued for minor alterations?

51. Which report is issued after periodic inspection?

52. Which regulation requires records to be kept of inspection and testing?

53. Which regulation requires safety documentation to be available to users?

54. Which regulation requires cables to be selected considering current‑carrying capacity?

55. Which regulation requires cables to be protected against mechanical damage?

56. Protection against spread of fire in wiring systems is covered by:

57. Which regulation requires cables in escape routes to be supported against premature collapse?

58. Which regulation requires consideration of voltage drop in cable design?

59. What is the maximum voltage drop allowed for lighting circuits?

60. What is the maximum voltage drop allowed for other circuits?